Publication
IRPS 2013
Conference paper
Reliability monitoring for highly leaky devices
Abstract
We demonstrate a new charge pumping (CP) methodology, frequency modulated CP (FMCP), that robustly treats metrology challenges associated with high gate leakage current. By moving to an AC coupled measurement, we are able to easily resolve small CP signals despite excessively high gate leakage current backgrounds. We demonstrate the utility of FMCP as a reliability monitoring tool in highly scaled and highly leaky devices. © 2013 IEEE.