Publication
Zeitschrift fur Physik B-Condensed Matter
Paper

Atomic resolution in dynamic force microscopy across steps on Si(111)7 × 7

View publication

Abstract

In this note we report the first observation of salient features of the Si(111)7 × 7 reconstructed surface across monatomic steps by dynamic atomic force microscopy (AFM) in ultrahigh vacuum (UHV). Simultaneous measurements of the resonance frequency shift Δf of the Si-cantilever and of the mean tunneling current Īf from the cleaned Si tip indicate a restricted range for stable imaging with true atomic resolution. The corresponding characteristics vs. distance reveal why feedback control via Δf is problematic, whereas it is as successful as in conventional STM via Īt. © Springer-Verlag 1996.